Tettex 2816: Manual Power Factor Test Set

$0.00

The primary application of the Tettrix 2816 instrument is to perform periodic maintenance inspections to evaluate the high voltage insulation losses of many types of apparatus. Additional functions are provided, which make this instrument ideal for detailed analysis of power transformer conditions.

SKU: Tettex-2816 Categories: ,

More Information

The Tettex 2816 Manual Power Factor Test Set is designed for onsite testing of high voltage distribution equipment

The rugged two piece design incorporates shock absorbing characteristics to facilitate transporting the instrument without affecting it’s precision.

Features:

  • Digital displays
    • Power loss direct or standardized to 10 kV
    • Power Factor PF (cos ϕ)
    • Dissipation factor (tan δ)
    • Test current
    • Test voltage
    • Test frequency
    • Capacitance
  • Two measurement inputs to accommodate AN SI/ IEEE (UST, G ST and G STg) testing without changing connections
  • Automatic  interference suppression
  • Built in printer
  • Including RS 232C
  • IEEE 488 output (optional)
  • 200 mA, 12 kV AC power supply
  • Automatic polarity reversal switch
  • Manual voltage adjustment
  • Measures while the voltage is being adjusted
  • Fast setup and measuring
  • Built in operator safety features
    • Safety ground monitor circuit to ensure safe connections between the high voltage ground and earth ground before high voltage can be turned on. A light on the power supply indicates the ground status.
    • Hand held safety push button switch
  • Other parameters that can be selected for display – Apparent power
    • Reactive power
    • Inductance
    • Quality factor
    • Magnetizing current
    • Iron loss current
  • Built in standard capacitor
  • Can be used with an external standard capacitor
  • Operator entry of the number of measurements to be averaged
  • Facilitates ratio entry for use with an external current comparator to extend the measuring range
  • Simplified color coordinated operator input controls
  • Retains last display and measuring mode setup when power is turned off
  • Plain language error messages are displayed on a 2 line 16 character LC D display
  • Permits entering up to seven ANSI temperature conversion tables to provide power factor printout standardized to 20 °C
  • Automatic date and time on report print outs
  • Operator entry of a test object identification number that will be printed on all reports
  • A built in hardware self test sequence
  • Field replaceable plug in printed circuit assemblies which are accessible from the front of the instrument
  • Front panel mounted HV fuses and circuit breaker

Measured parameters:

Capacitance CX

at 200 mA, 50 Hz (60 Hz)

for 12 kV max. 53 nF (44 nF)

for 1 kV max. 630 nF (530 nF)

Resolution 0.01 pF

Limits of error ± 0.05 % rdg ± 1 dig

Inductance

Conditions 31 µA < IX < 200 mA

e.g. for 12 kV/50 Hz 190 H … 1273 kH

Resolution 0.1 mH

Limits of error ± 0.5 % rdg ± 2 dig

Dissipation factor (tan δ)

Range 0 … 9.99

Resolution 0.0001

Limits of error ± 1 % rdg ± 0.0001

Power factor PF (cos ϕ)

Range 0 … 1.00

Resolution 0.0001 Limits of error ± 1 % rdg ± 0.0001

Test voltage

Range 0 … 12.00 kV

Optional 0 … 2.00 kV

Resolution 0.001 kV

Limits of error ± 1.0 % rdg ± 2 dig

Test current

Range 0 … 15.00 A

Resolution 0.001 mA

Limits of error ± 1.0 % rdg ± 2 dig

Test frequency

Range 45.00 … 65.00 Hz

Resolution 0.01 Hz

Limits of error ± 0.02 % rdg

Quality factor

Range 0.1 … 9999

Measuring time

First reading 4 sec

Update readings 0.6 sec intervals

Display range of other parameters

Apparent power (S) 0 mVA … 999.9 kVA

Actual power (P) 0 mW … 999.9 kW Reactive power (Q) 0 mVAr … 999.9 kVAr

Magnetizing current (Im) 0 … 999.9 A

Iron loss current (Ife) 0 … 999.9 A

Standard capacitor

Internal ≈100 pF / 12 kV max.

Test current limitations

C N : The external capacitor input current range is limited to greater than 31 µA and less than 15 mA.

C X: A and B test object capacitances are limited to 15 A maximum.

High voltage output

The high voltage section has a dual range (12 kV) manual voltage adjustment:

Voltage 0.1 kV … 12 kV

Current 200 mA (continuous)

Optional range:

Voltage 0 … 2 kV

Current 5 mA

Stated error is based on the following test conditions

Standard capacitor CN = 100 pF

Test voltage ≥ 1000 V

Unknown capacitance 50 · C N < C X < 2000 · C N 31 µA < IX < 15 A

The ranges shown are limited by the power supply limits of 200 mA, 12 kV. For ranges of the 2816 with external standard refer to the “range extension” section of this specification.

Operating temperature            

5 °C to + 40 °C

Mains supply

Voltage 230 V or 115 V ± 10%

Current (no load) 180 mA / 360 mA

           (full load) 11 A / 22 A

Frequency 50/ 60 Hz

Weights and dimensions

Two interlocked stacking cases

(W x H x D) 500 x 310 x 470 mm

(20.8 x 12.8 x 24.2 in) each

– Measuring instrument 40 kg (88 Ib)

– HV-transformer/control with support bracket 86 kg (189 Ib)

– Case with cables 24 kg (53 Ib)

Applicable standards

The measuring system is designed in accordance with the appropriate sections of the following specifications:

– ANSI / IEEE C 57.12.90

– VDE 0411/Part 1

– IEC 348 / Safety category I

– IEC 359