Altek 942: Frequency Calibrator

$0.00

Use the Altek 942 Frequency Calibrator in the field to check the signals from your flowmeter pickups, velocity and motion detectors, Frequencies can be directly measured from 0.01 Hz to 250.00 KHz in four frequency ranges.

SKU: altek-942 Categories: ,

More Information

Calibrate your turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators and any other frequency devices in the shop, plant or field with the Altek 942 Frequency Calibrator

Measure from 0.01 Hz to 250.00 KHz with resolution down to 0.01Hz. For your slower signals, source or measure from 0.1 to 2000.0 counts per minute (CPM) or from 10 to 20000 counts per hour (CPH). Quickly indicate process signals, no more waiting around with stopwatch and calculator.

Measure extremely slow frequencies (less than 1 Hz) with high resolution using CPM & CPH. Instead of displaying 1/2 Hz as 0.5 Hz (1 digit of resolution) as most with frequency counters you can display it as 30.0 CPM (3 digits of resolution) or as 1800 CPH (4 digits of resolution). You can now measure these slow signals in seconds with the Model 942 instead of many minutes needed with a totalizer, stopwatch and calculator. Measure signals from 30 mV to 40 V peak-topeak with a minimum pulse width of 2 microseconds.

Features:

  • Laboratory Accurate: 0.001% of setting (10 PPM).
  • Six Real World Ranges: 1 to 20000 Counts-Per-Hour (CPH), 0.1 to 2000.0 Counts-Per-Minute (CPM), 0.01 to 999.99 Hz, 0.001 to 99.999 kHz and 0.01 to 250.00 kHz.
  • Calibrate Totalizers: Output a selectable number of pulses over 1 to 99 minutes to verify totalizer readings. The calibrator automatically stops outputting when the selected number of pulses has been sent to the totalizer.
  • Count Pulses: Use as a timed totalizer to check flowmeter and integrator outputs. Built-in totalizer to 99999 counts with optional timed operation to 99 minutes up to maximum rate of 100 Hz.
  • Save Time: Calibrate flowmeters, frequency transmitters and integrators. Use CPH and CPM ranges to directly display extremely slow signals, eliminating waiting with stop watch and calculator.
  • Match Your Receiver’s Input: Select from sine, zero crossing square or zero based square wave output. Adjustable amplitude from 50 mV to 12 V p-p.
  • Reads All Waveforms: From 40 mV to 240 V peak. Instantly recall the minimum and maximum frequency measured.
  • Quik-Chek Switch: Instantly recall 18 output frequencies (three for each range). Fast, easy adjustment with a multi-speed digital potentiometer.
  • Built-In Leads: Large alligator clips for easy connections. Optional BNC connector available.
  • Long Battery Life: Six AA alkaline batteries last over 40 hours.