× Close

High Voltage (HVI) VLF-65E: Very Low Frequency AC Hipot

$0.00

With the HVI VLF-65E Hipot, test programming, data retrieval, and custom PC software are intuitive and easy to learn. This unit is portable, affordable, and designed to withstand years of field use.

SKU: VLF-65E3 Categories: ,

More Information

The High Voltage Inc VLF-65E is a top performer from the latest generation of HVI VLF AC hipots using a dry-type, air-cooled, solid state design with microprocessor control

Test programming, data retrieval, and custom PC software are intuitive and easy to learn. This unit is portable, affordable, and designed to withstand years of field use.

Its 0 – 65 kV AC peak/0 – 46 kV AC RMS output voltage meets world standards for acceptance testing up to 35 kV class cable, and its sine wave output pairs easily with optional tan delta and partial discharge measurement systems.

Features:

  • VLF and DC output
  • Programmable test sequences
  • Automatic & manual control
  • USB port for exporting data
  • Wireless computer interface for remote control operation and data upload
  • Onscreen tan delta data display with optional TD-34E
  • XBee wireless for better signal sustainability and broader range than Bluetooth

Specifications:

The VLF-65E meets the following specifications: IEEE 400.2, IEEE 400, IEC 60060-3, CENELEC HD 620/621, VDE DIN 0276-620/621. IEEE 433 for motors/generators.

Input: 100 V AC – 265 V AC, 50 Hz/60 Hz, 20 A max
Output: VLF sinewave: 0 – 65 kV AC peak/46 kV AC RMS @ 28 mA RMS
VLF square wave: 0 – 65 kV AC peak @ 22 mA
DC: 0 – ± 65 kV @ 22 mA
Sheath test – programmable
Duty: Continuous
Frequency: 0.1 Hz to 0.01 Hz in steps of 0.01 Hz
Load Rating: 1.0 μF @ 0.10 Hz @ 65 kV
2.0 μF @ 0.05 Hz @ 65 kV
5.0 μF @ 0.02 Hz @ 65 kV
10.0 μF @ 0.01 Hz @ 65 kV
μF rating increases at lower voltages
Ex: 1.4 μF @ 0.1 Hz @ 47 kV peak
Voltmeter: Voltage kV peak or RMS, +/-1% accuracy
Current Meter: mA peak or RMS, +/-1% accuracy
Calculated: Capacitance, resistance, tan delta flash overvoltage, time to failure
Fault Response: Smart Fault Management – fault burning or shutdown on fault
Reports/Data: Up to 50 test records can be stored in non-volatile memory or removable USB memory stick
PC Interface: USB and XBee wireless
PC Software: Remote control & test data reporting
Size & Weight:
(W x D x H)
22 x 14.5 x 26 in., 150 lb
559 x 369 x 660 mm, 68 kg
Output Termination: 20’/6 m flexible x-ray, ground #2 – 20’/6 m #10 test leads, ground hook, line cords

Documentation:

Equipment Brochure


Additional information

Hot Product

Home Page Item?

Manufacturer

UOM - Unit of Measure

Reviews

There are no reviews yet.

Be the first to review “High Voltage (HVI) VLF-65E: Very Low Frequency AC Hipot”

Your email address will not be published. Required fields are marked *

Related Products